15 building permits since 2003 in Mesa city, AZ — $7,500 in reported job value over 6 permits that state one.

Building permits
15
Reported job value
$7.5K
Active
2003–2007
Latest permit
Oct 11, 2007

Where it works

Counties shaded by permits filed there; the dashed outline encloses every permit location.

Permits by county, fewer to moreOperating area

Busiest jurisdictions

  • Mesa city, AZ15

Permits by year

By issue date (application date where there is none).

048
8
20032004200520062007
View as table
YearPermits
20031
20048
20052
20062
20072

Type of work

Permits describing each kind of work; one permit can cover several.

  • Pools & hot tubs14
  • Gas13
  • Plumbing12
  • Additions1

Permit types

As the building departments classify them.

  • RES11
  • Res (OTH) -- Plumbing3
  • Com (OTH) -- Plumbing1

Recent permits

The 8 newest on file.

DateTypeWorkJurisdictionJob value
Oct 11, 2007Res (OTH) -- PlumbingINSTALL 50' OF 1 1/4" PE GASLINE FROM METER TO POOL HEATER 400K BTU'S. GASLINE TO BE 18" BELOW GRADE WITH #18 GAUGE TRACER WIRE. EXISTING 80K BTU'S. TOTAL WITH Mesa—
May 11, 2007Res (OTH) -- PlumbingINSTALL 50' OF 1 1/4" PE GASLINE FROM METER TO POOL HEATER 400K. GASLINE TO BE 18" BELOW GRADE WITH #14 GAUGE TRACER WIRE. SW GAS SERVICE AREA. MAY NEED TO UPGRMesa—
Apr 6, 2006Com (OTH) -- PlumbingSCOPE OF WORK INCLUDES THE INSTALLATION OF 1" P.E. PIPE FROM 400K POOL HEATER TO 35K FUTURE FIREPLACE (ADDITIONAL PERMIT REQUIRED AT TIME OF FIREPLACE INSTALLATMesa$2,000
Feb 3, 2006Res (OTH) -- PlumbingGAS LINE FROM METER TO POOL HEATER 400K. RUN 85 FEET OF 1 1/2"PE PIPING 18"COVER, 18 GA WIRE. EXISTING 250 CLASS GAS METER. UPGRADE TO A ROTARY 8 CLASS GAS METEMesa$1,000
Aug 25, 2005RESGAS LINE FOR POOL HEATER. RUN 50 FEET OF 1 1/2"PE PIPING TO NEW POOL HEATER 400K. SW GAS AREA.Mesa—
May 2, 2005RESRUN 2" PE GASLINE TO NEW 400K POOL HEATER, RUN 15' OF 1" PE, AND 134' OF 1 1/4" PE GASLINE. APPLIANCES INCLUDE 4 35K BTU UL LISTED FIRE RINGS AND 65K BTU BBQ. NMesa—
Dec 15, 2004RESRUN 50' OF 1 1/4" PE GASLINE TO NEW 400K BTU POOL HEATER. GASLINE TO BE RUN A MIN OF 18" DEEP WITH #14GA TRACER WIRE. NEW TOTAL BTU LOAD IS 485 UPGRADE METER TOMesa—
Oct 11, 2004RESP.E. GAS LINE TO 400,000 BTU POOL HEATER TO BE RUN 200' OF 2" 18" UNDERGROUND, WITH 14 GAUGE TRACER WIRE & APPROVED TRANSITION RISER. UPGRADE GAS METER TO A ROTMesa$1,000