Contractor · HVAC
PERCO MECHANICAL INC
17 building permits since 2011 in Boulder city, CO and Boulder County, CO — $91,770 in reported job value over 17 permits that state one.
- Building permits
- 17
- Reported job value
- $91.8K
- Active
- 2011–2012
- Latest permit
- Dec 11, 2012
Where it works
Counties shaded by permits filed there; the dashed outline encloses every permit location.
Busiest jurisdictions
- Boulder city, CO16
- Boulder County, CO1
Permits by year
By issue date (application date where there is none).
0510
10
20112012
View as tableHide table
| Year | Permits |
|---|---|
| 2011 | 10 |
| 2012 | 7 |
Type of work
Permits describing each kind of work; one permit can cover several.
- HVAC17
- Heat pumps10
- Telecom2
- Electrical2
- Remodels1
Permit types
As the building departments classify them.
- Mechanical Permit16
- Commercial Remodel1
Recent permits
The 8 newest on file.
| Date | Type | Work | Jurisdiction | Job value |
|---|---|---|---|---|
| Dec 11, 2012 | Commercial Remodel | Install 9 New Split System A/C Units | Boulder County | $18,750 |
| Oct 18, 2012 | Mechanical Permit | Installation of 2 ton mini-split system, 16 seer for computer room on northwestern wall. Mechanical permit only, electrical by separate permit. | Boulder | $3,300 |
| Aug 6, 2012 | Mechanical Permit | Installation of minisplits for 6, 2-ton and 2, 3-ton 16 SEER comfort cooling units located within the telecom rooms. | Boulder | $8,300 |
| Jun 22, 2012 | Mechanical Permit | Installation of two replacement RTUs -- one unit a 20 ton cooling & heating unit, EER 10.8 minimum; the other a 5 ton cooling & heating unit, 13.0 SEER minimum. | Boulder | $11,000 |
| May 23, 2012 | Mechanical Permit | Installation of a replacement forced-air furnace (high-efficiency) and a replacement 2.5 ton a/c unit. (13.0 SEER minimum). | Boulder | $5,700 |
| Mar 28, 2012 | Mechanical Permit | Two replacement RTUs, 4 ton and 5 ton, same size and location. 13 SEER | Boulder | $6,000 |
| Feb 29, 2012 | Mechanical Permit | Installation of a 3 ton mini-split a/c unit for a telecom room. 13.0 SEER minimum. Electrical by separate permit & separate contractor. | Boulder | $2,000 |
| Dec 27, 2011 | Mechanical Permit | Mechanical permit to replace rooftop unit | Boulder | $1,700 |
Permit status
Where its permits stand, as the departments report them.
- Completed11
- Void6
Compiled from public building permit records. A contractor here is the name on the permits, with spelling variants combined where they work the same area; the same name in distant markets is listed separately. Job values are as reported on the permits.