Contractor · Electrical
S & S ELECTRIC COMPANY (E000)
21 building permits since 2020 in Memphis city, TN; Arlington town, TN and Shelby County, TN.
- Building permits
- 21
- Reported job value
- —
- Active
- 2020–2025
- Latest permit
- Sep 8, 2025
Where it works
Counties shaded by permits filed there; the dashed outline encloses every permit location.
Busiest jurisdictions
- Memphis city, TN17
- Arlington town, TN2
- Shelby County, TN2
Permits by year
By issue date (application date where there is none).
036
6
20202021202320242025
View as tableHide table
| Year | Permits |
|---|---|
| 2020 | 4 |
| 2021 | 6 |
| 2023 | 1 |
| 2024 | 6 |
| 2025 | 4 |
Type of work
Permits describing each kind of work; one permit can cover several.
- Electrical21
- HVAC8
- Kitchens2
- Fire sprinklers2
- Remodels1
- Plumbing1
- Generators1
- Water heaters1
Permit types
As the building departments classify them.
- COMMERCIAL ELECTRICAL PERMIT19
- RESIDENTIAL ELECTRICAL PERMIT2
Recent permits
The 8 newest on file.
| Date | Type | Work | Jurisdiction | Job value |
|---|---|---|---|---|
| Sep 8, 2025 | COMMERCIAL ELECTRICAL PERMIT | Install (2) light Fixtures & (3) 120v receptacles in five new offices. | Shelby County | — |
| Sep 4, 2025 | COMMERCIAL ELECTRICAL PERMIT | Rework and existing 480v 1200 amp circuit to a new chiller. | Memphis city | — |
| Jun 3, 2025 | COMMERCIAL ELECTRICAL PERMIT | Replace (12) new troffer light fixtures. rework (3) 120v drops and install (2) 20/2 208v circuits for Split units. | Arlington town | — |
| Jan 3, 2025 | COMMERCIAL ELECTRICAL PERMIT | Install 15-amp feed for outdoor condensing unit. Install 50 amp feed for indoor unit. | Memphis city | — |
| Sep 30, 2024 | COMMERCIAL ELECTRICAL PERMIT | Replace 400a 480v feeder, Replace Boiler #3 480v starter with a 20hp VFD, Refeed an existing trough with a 90a 480v circuit, Install (1) 20a 120v ckt to control | Memphis city | — |
| Sep 27, 2024 | COMMERCIAL ELECTRICAL PERMIT | Replace the existing starter for a chiller with a VFD and rework the existing 600a feeder. Also install a new 20a 120v circuit refrigerant circuit. | Memphis city | — |
| Sep 13, 2024 | COMMERCIAL ELECTRICAL PERMIT | Food court remodel: Replace existing lights. Install new 20-amp 208-volt 3 phase circuit for exhaust fan, New 20-amp 120-volt circuit for Ansul System, New rece | Memphis city | — |
| Jul 17, 2024 | COMMERCIAL ELECTRICAL PERMIT | Install (1) 400a 3 pole 480v breaker and (1) 225a 3 pole 480v breaker in the MSB to feed a new 4000a DP, 225a UPS and a 225a DP. The 225a DP will feed (1) 45kva | Arlington town | — |
Compiled from public building permit records. A contractor here is the name on the permits, with spelling variants combined where they work the same area; the same name in distant markets is listed separately. Job values are as reported on the permits.